4.5 Article

Volumetric Measurement of Subretinal Blebs Using Microscope-Integrated Optical Coherence Tomography

Journal

Publisher

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/tvst.7.2.19

Keywords

subretinal space; gene therapy; retina; drug delivery; optical coherence tomography

Categories

Funding

  1. National Institutes of Health/National Eye Institute Biomedical Research Partnership Grant [R01-EY023039]
  2. National Science Foundation Graduate Research Fellowship
  3. Ford Foundation Predoctoral Fellowship
  4. T-32 NIH Medical Imaging Training Grant
  5. NATIONAL EYE INSTITUTE [R01EY023039] Funding Source: NIH RePORTER

Ask authors/readers for more resources

Purpose: We advance studies of subretinal treatments by developing a microscope-integrated optical coherence tomography (MIOCT) image-based method for measuring the volume of therapeutics delivered into the subretinal space. Methods: A MIOCT image-based volume measurement method was developed and assessed for accuracy and reproducibility by imaging an object of known size in model eyes. This method then was applied to subretinal blebs created by injection of diluted triamcinolone. Bleb volumes obtained from MIOCT were compared to the intended injection volume and the surgeon's estimation of leakage. Results: Validation of the image-based volume measurement method showed accuracy to +/- 1.0 mu L (6.0% of measured volume) with no statistically significant variation under different imaging settings. When this method was applied to subretinal blebs, four of 11 blebs without surgeon-observed leakage yielded a mean volume of 32 +/- 12.5 mu L, in contrast to the intended 50 mu L volume injected from the delivery device. This constituted a mean difference of -18 mu L (mean percent error, 36 +/- 25%). For all 11 blebs, the surgeon's estimations of leakage were significantly different from and showed no correlation with the volume loss based on image-based volume measurements (P < 0.001, paired t-test; intraclass correlation = 0). Conclusions: We validated an accurate and reproducible method for measuring subretinal volumes using MIOCT. Use of this method revealed that the intended volume might not be delivered into the subretinal space. MIOCT can allow for accurate assessment of subretinal dose delivered, which may have therapeutic implications in evaluating the efficacy and toxicity of subretinal therapies.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available