In Situ Generation of Electron Donor to Assist Signal Amplification on Porphyrin-Sensitized Titanium Dioxide Nanostructures for Ultrasensitive Photoelectrochemical Immunoassay

Journal

ACS APPLIED MATERIALS & INTERFACES
Volume 7, Issue 42, Pages 23812-23818

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsami.5b08742

Keywords

photoelectrochemical immunoassay; porphyrins; carcinoembryonic antigen; titanium dioxide nanostructures; hybrid nanostructures; photocurrent

Funding

  1. National Natural Science Foundation of China [41176079, 21475025]
  2. National Science Foundation of Fujian Province [2014J07001]
  3. Key Science Project (Type A) of Fujian Provincial Department of Education of China [JA12021]
  4. Program for Changjiang Scholars and Innovative Research Team in University [IRT1116]

Ask authors/readers for more resources

An ultrasensitive photoelectrochemical (PEG) immunoassay protocol for quantitative detection of low-abundant proteins at a low potential was designed by utilizing porphyrin-sensitized titanium dioxide (TiO2) nanostructures. Experimental results demonstrated that the water-soluble 5,10,15,20-tetra(4-sulfopheny1)-21H,23H-porphyrin (TSPP) could be bound onto titanium dioxide via the sulfonic group. TSPP-sensitized TiO2 nanostructures exhibited better photoelectrochemical responses and stability in comparison with TiO2 nanoparticles alone under continuous illumination. Using carcinoembryonic antigen (CEA) as a model analyte, a typical PEG immunosensor by using TSPP-TiO2 as the affinity support of anti-CEA capture antibody (Ab(1)) to facilitate the improvement of photocurrent response was developed. Bioconjugates of secondary antibody and glucose oxidase with gold nanopartides (Ab(2)/GOx-AuNPs) was introduced by an antigen antibody immunoreaction. AuNP acted as a powerful scaffold to bind with bioactive molecules, while GOx catalyzed glucose to in situ generate hydrogen peroxide (H2O2). The generated H2O2 as a sacrificial electron donor could be oxidized by the photogenerated holes to assist the signal amplification at a low potential under light excitation, thus eliminating interference from other species coexisting in the samples. Under optimal conditions, the PEG immunosensor showed a good linear relationship ranging from 0.02 to 40 ng mL(-1) with a low detection limit of 6 pg mL(-1) CEA. The precision, reproducibility, and specificity were acceptable. In addition, the method accuracy was also evaluated for quantitatively monitoring human serum samples, giving results matching with the referenced CEA ELISA kit.