4.7 Article

Modularization and Response Curve Engineering of a Naringenin-Responsive Transcriptional Biosensor

Journal

ACS SYNTHETIC BIOLOGY
Volume 7, Issue 5, Pages 1303-1314

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acssynbio.7b00419

Keywords

transcriptional biosensors; response curve engineering; naringenin; dynamic range; operational range; Escherichia coli

Funding

  1. Institute for the Promotion of Innovation through Science and Technology in Flanders (IWT-Vlaanderen)
  2. project CondEx [FWO-G.0321.13 N]
  3. BOF-IOP project (Bijzonder Onderzoeksfonds-Interdisciplinair Onderzoeksproject), MLSB [BOF16/IOP/040]

Ask authors/readers for more resources

To monitor the intra-and extracellular environment of micro-organisms and to adapt their metabolic processes accordingly, scientists are reprogramming nature's myriad of transcriptional regulatory systems into transcriptional biosensors, which are able to detect small molecules and, in response, express specific output signals of choice. However, the naturally occurring response curve, the key characteristic of biosensor circuits, is typically not in line with the requirements for real-life biosensor applications. In this contribution, a natural LysR-type naringenin-responsive biosensor circuit is developed and characterized with Escherichia coli as host organism. Subsequently, this biosensor is dissected into a clearly defined detector and effector module without loss of functionality, and the influence of the expression levels of both modules on the biosensor response characteristics is investigated. Two collections of ten unique synthetic biosensors each are generated. Each collection demonstrates a unique diversity of response curve characteristics spanning a 128-fold change in dynamic and 2.5-fold change in operational ranges and 3-fold change in levels of Noise, fit for a wide range of applications, such as adaptive laboratory evolution, dynamic pathway control and high-throughput screening methods. The established biosensor engineering concepts, and the developed biosensor collections themselves, are of use for the future development and customization of biosensors in general, for the multitude of biosensor applications and as a compelling alternative for the commonly used LadI-, TetR- and AraC-based inducible circuits.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available