4.6 Article

Automated Segmentation of the Choroid from Clinical SD-OCT

Journal

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Volume 53, Issue 12, Pages 7510-7519

Publisher

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/iovs.12-10311

Keywords

-

Categories

Funding

  1. [NEI-EY019112]
  2. [R01 EY018853]
  3. [NEI-EY017451]
  4. [NEI-EY017066]
  5. [VA 1I01CX000119]

Ask authors/readers for more resources

PURPOSE. We developed and evaluated a fully automated 3-dimensional (3D) method for segmentation of the choroidal vessels, and quantification of choroidal vasculature thickness and choriocapillaris-equivalent thickness of the macula, and evaluated repeat variability in normal subjects using standard clinically available spectral domain optical coherence tomography (SD-OCT). METHODS. A total of 24 normal subjects was imaged twice, using clinically available, 3D SD-OCT. A novel, fully-automated 3D method was used to segment and visualize the choroidal vasculature in macular scans. Local choroidal vasculature and choriocapillaris-equivalent thicknesses were determined. Reproducibility on repeat imaging was analyzed using overlapping rates, Dice coefficient, and root mean square coefficient of variation (CV) of choroidal vasculature and choriocapillaris-equivalent thicknesses. RESULTS. For the 636 mm(2) macula-centered region as depicted by the SD-OCT, average choroidal vasculature thickness in normal subjects was 172.1 mu m (95% confidence interval [CI] 163.7-180.5 mu m) and average choriocapillaris-equivalent thickness was 23.1 mu m (95% CI 20.0-26.2 mu m). Overlapping rates were 0.79 +/- 0.07 and 0.75 +/- 0.06, Dice coefficient was 0.78 +/- 0.08, CV of choroidal vasculature thickness was 8.0% (95% CI 6.3%-9.4%), and of choriocapillaris-equivalent thickness was 27.9% (95% CI 21.0%-33.3%). CONCLUSIONS. Fully automated 3D segmentation and quantitative analysis of the choroidal vasculature and choriocapillaris-equivalent thickness demonstrated excellent reproducibility in repeat scans (CV 8.0%) and good reproducibility of choriocapillaris-equivalent thickness (CV 27.9%). Our method has the potential to improve the diagnosis and management of patients with eye diseases in which the choroid is affected. (Invest Ophthalmol Vis Sci. 2012; 53: 7510-7519) DOI:10.1167/iovs.12-10311

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available