4.7 Article

QbD approach by computer aided design and response surface methodology for molecularly imprinted polymer based on magnetic halloysite nanotubes for extraction of norfloxacin from real samples

Journal

TALANTA
Volume 184, Issue -, Pages 266-276

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2018.02.056

Keywords

Halloysite nanotubes; Magnetic imprinted polymers; Solid phase extraction; Norfloxacin; Serum samples; Environmental water; QbD approach

Funding

  1. China Scholarship Consul (CSC) [2013012007]
  2. Independent Innovation Fund Project of Agricultural Science and Technology of Jiangsu Province [CX(17)1003]
  3. Guizhou Provincial Science and Technology Department Joint Fund Project (Qian Kehe LH word) [7076]

Ask authors/readers for more resources

This article describes the development, optimization, and evaluation of a novel composite imprinted polymer, on the basis of magnetic halloysite nanotubes (MHNTs-MIPs) using Quality by Design (QbD) approach combining computer simulation and response surface methodology. Norfloxacin, methacrylic acid, and ethylene glycol dimethacrylate were used as template, functional monomer and cross-linker, respectively. As a comparison, two MHNTs-MIPs have been prepared with the most suitable functional monomer methacrylic acid (MAA) along with acrylamide (AM). To explain the adsorption behavior, adsorption kinetics and isotherms were studied. Magnetic halloysite nanotubes molecularly imprinted polymers prepared from MAA (MHNTs-M1131) displayed a high adsorption capacity (349 mu g mg(-1)) toward NOR. A magnetic imprinting solid phase extraction method coupled with high performance liquid chromatography (MHNTs-MISPE-HPLC-UV) was developed for the determination of NOR in serum and water samples, by applying MHNTs-MIP as a sorbent. The recoveries from 83.76% to 103.30% in water and from 90.46% to 99.78% in serum were obtained. Besides remarquable mechanical properties and specific recognition of MHNTs-MIP toward template molecule. It could be also collected and separated fastly by external magnetic field. Moreover, MHNTs-MIPs could be reused for several cycles with the recovery range from 83.25% to 100.96% for water sample and from 85.65% to 100.33% for serum sample. These analytical results of serum and water samples showed that the proposed method based on MHNTs-MIPs is applicable for fast and selective extraction of therapeutic agents from biological fluids and environmental water.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available