4.7 Article

Affinity capture surface carboxyl-functionalized MoS2 sheets to enhance the sensitivity of surface plasmon resonance immunosensors

Journal

TALANTA
Volume 185, Issue -, Pages 174-181

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2018.03.073

Keywords

Molybdenum disulfide (MoS2); Carboxyl-functionalized; Bovine serum albumin (BSA); Surface plasmon resonance (SPR); Biosensor

Funding

  1. Ministry of Science and Technology of the Republic of China, Taiwan [MOST 103-2221-E-003-008, MOST 104-2314-B-195-015, MOST 105-2221-E-003-027, MOST 106-2221-E-003-020]

Ask authors/readers for more resources

The development of functionalized molybdenum disulfide (MoS2) has led to a new trend in the biosensing field, owing to its high sensitivity and bio-affinity characteristics with regards to the simple synthesis of carboxyl-functionalized MoS2 nanocomposites. In this study, we used monochloroacetic acid (MCA) to successfully modify carboxyl-MoS2. The efficiency of this MCA modification method showed a higher -COOH group content of 30.1%, mainly due to chlorine atoms occupying the MoS2 sulfur vacancy to allow for the formation of a strong bonding effect. This then enhanced the surface area of -COOH and improved the formation of covalent bonds between proteins. We demonstrated that MoS2-COOH-based surface plasmon resonance (SPR) chips can provide excellent sensitivity and high affinity for immunoassay biomolecules detected in a low sample volume of 20 mu l. With respect to the shifts of the SPR angles of the chips, the high binding affinity at a BSA concentration of 14.5 nM for a MoS2-COOH chip, a MoS2 chip and a traditional SPR chip are 4.69 m degrees, 2.49 m degrees and 1.53 m degrees, respectively. In addition, the MoS2-COOH chip could amplify the SPR angle response by 3.1 folds and enhance the high association fate of ka by 212 folds compared to MoS2 and traditional SPR chips. The results thus obtained revealed that the overall affinity binding value, K-A, of the MoS2-COOH chip can be significantly enhanced by up to similar to 6.5 folds that of the MoS2 chip. In summary, the excellent binding affinity, biocompatible and high sensitivity suggest the potential of the clinical application of this MoS2-COOH-based SPR chip detection method for in vitro diagnostic and point-of-care testing devices.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available