4.7 Article

Development of flow systems incorporating membraneless vaporization units and flow-through contactless conductivity detector for determination of dissolved ammonium and sulfide in canal water

Journal

TALANTA
Volume 177, Issue -, Pages 34-40

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2017.09.037

Keywords

Membraneless vaporization unit; Contactless conductivity detector; Ammonium; Sulfide

Funding

  1. Faculty of Graduate Studies, Mahidol University
  2. Thailand Research Fund [MRG5480092]
  3. Agricultural Research Development Agency [PRP5605020800]
  4. Mahidol University

Ask authors/readers for more resources

Use of membraneless vaporization (MBL-VP) unit with two cone-shaped reservoirs is presented for on-line separation and detection of non-volatile species. A flow system comprising two sets of MBL-VP units with a single in-house capacitively coupled contacdess conductivity detector (C4D) was developed for dual determination of ammonium and sulfide ions. Using the continuous-flow section, two zones (280 mu L) of a sample, either mixed with sodium hydroxide (for ammonium) or hydrochloric acid (for sulfide), are separately delivered into the donor reservoir of the MBL-VP units. The acceptor reservoir contains either 150 mu L of 15 mu M HCl solution (for ammonia) or pure water (for hydrogen sulfide), respectively. Vaporization and trapping of the ammonia or hydrogen sulfide gas from the donor reservoir into the liquid acceptor cone occur concurrently in the two separate MBL-VP units. After trapping the gas for 3 min, the two 150-mu L liquid acceptors are sequentially aspirated through the C4D flow cell for recording the changes in the conductivity. Linear calibrations were obtained for ammonium from 5 to 80 mu M (Volt = (0.0134 +/- 0.0003) [NH4+] - (0.01 +/- 0.01), r(2) = 0.998) and for sulfide from 5 to 200 M (Volt = (0.0335 +/- 0.0009) [S2-] - (0.13 +/- 0.09), r(2) = 0.996). Analysis time for both analytes is only 320 s. Our method was applied to analyze canal water samples. The results agree well with membrane gas-diffusion flow injection techniques, using bromothymol blue for ammonium and methylene blue for sulfide. Recoveries ranged froth 95% to 104%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available