4.7 Article

High-performance fibre-optic humidity sensor based on a side-polished fibre wavelength selectively coupled with graphene oxide film

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 255, Issue -, Pages 57-69

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2017.08.042

Keywords

Fibre optics; Side-polished fibre; Optical fibre sensing; Graphene oxide; Humidity sensor

Funding

  1. National Natural Science Foundation of China [61675092, 61505069, 61405075, 61475066]
  2. Natural Science Foundation of Guangdong Province [2016A030313079, 2015A030306046, 2016A030310098, 2014A030313377, 2014A030310205, 2015A030313320, 2016A030311019]
  3. Science and technology projects of Guangdong Province [2017A010102006, 2013B090600045, 2015A020213006, 2015B010125007, 2016B010111003, 2016A010101017]
  4. Science & Technology Project of Guangzhou [201707010396, 201506010046, 201607010134]

Ask authors/readers for more resources

A high-performance humidity sensor based on a side-polished single-mode fibre (SPF) coated with graphene oxide film was fabricated with a wheel side-polishing technique and spontaneous evaporation. The wavelength-selective coupling gave rise to a loss dip in the transmitted spectrum when a phase match condition was satisfied at a given resonant wavelength. The swelling effect of GO under high RH, which was confirmed by XRD and a spectroscopic ellipsometer, could increase the GO film thickness and led to a redshift at resonant wavelength. Experimental results show that the GO-film-coated SPF (GFC-SPF) is capable of working in two modes: tracing-wavelength mode and intensity variation mode. For the two working modes, the GFC-SPF has high sensitivity, good reversibility, good repeatability and excellent linearity. For the tracing-wavelength mode, a very high sensitivity of 0.145 nm/RH% and a high linear correlation of 99.6% were achieved in a low RH range of 32%-85%, while an ultrahigh sensitivity of 0.915 nm/RH% and a linear correlation of 98.7% were achieved in a high RH range of 85%-97.6%. For the intensity variation mode, a high sensitivity of 0.427 dB/RH% and an excellent linearity correlation of 99.8% were achieved in a wide RH range of 58.2%-92.5%. Such a high performance allows GFC-SPF to have widespread potential applications, such as in the fields of biology, chemical processing and food processing. (C) 2017 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available