4.6 Article

A Miniature Binocular Endoscope with Local Feature Matching and Stereo Matching for 3D Measurement and 3D Reconstruction

Journal

SENSORS
Volume 18, Issue 7, Pages -

Publisher

MDPI
DOI: 10.3390/s18072243

Keywords

endoscope; binocular stereoscopic vision; local feature descriptor; stereo matching; 3D measurement; 3D reconstruction

Funding

  1. National Nature Science Foundation of China [31271069]
  2. Shanghai Aerospace Science and Technology Innovation Fund [SAST2016084]

Ask authors/readers for more resources

As the traditional single camera endoscope can only provide clear images without 3D measurement and 3D reconstruction, a miniature binocular endoscope based on the principle of binocular stereoscopic vision to implement 3D measurement and 3D reconstruction in tight and restricted spaces is presented. In order to realize the exact matching of points of interest in the left and right images, a novel construction method of the weighted orthogonal-symmetric local binary pattern (WOS-LBP) descriptor is presented. Then a stereo matching algorithm based on Gaussian-weighted AD-Census transform and improved cross-based adaptive regions is studied to realize 3D reconstruction for real scenes. In the algorithm, we adjust determination criterions of adaptive regions for edge and discontinuous areas in particular and as well extract mismatched pixels caused by occlusion through image entropy and region-growing algorithm. This paper develops a binocular endoscope with an external diameter of 3.17 mm and the above algorithms are applied in it. The endoscope contains two CMOS cameras and four fiber optics for illumination. Three conclusions are drawn from experiments: (1) the proposed descriptor has good rotation invariance, distinctiveness and robustness to light change as well as noises; (2) the proposed stereo matching algorithm has a mean relative error of 8.48% for Middlebury standard pairs of images and compared with several classical stereo matching algorithms, our algorithm performs better in edge and discontinuous areas; (3) the mean relative error of length measurement is 3.22%, and the endoscope can be utilized to measure and reconstruct real scenes effectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper