4.1 Review

Analysis of Complications After Button Battery Ingestion in Children

Journal

PEDIATRIC EMERGENCY CARE
Volume 34, Issue 6, Pages 443-446

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/PEC.0000000000001413

Keywords

button battery; ingestion; complications

Ask authors/readers for more resources

Aim Button battery ingestion (BBI) in children may cause severe complications. This analysis is a literature review of complications after pediatric BBI. Methods Literature was searched on PubMed (1995-2015) using the terms button battery, ingestion, and children. End points were age, type and diameter of battery, complications, affected organ, and fatality. Results A total of 31 publications were analyzed. Patients from 4 months to 19 years old were included (n = 136,191, with n = 102,143 or 75% aged <6 y). In 6262, the diameter of the battery was documented. Batteries of 20 mm or greater in size were more prone to complications (n = 226). With regard to the anatomy, BBI caused complications mainly in the esophagus (n = 88, 38.94%). Sixty-one fatal outcomes were reported. Conclusions Children younger than 6 years are the most prone to BBI, with lithium batteries of 20 mm or greater in size associated with complications. Complications have been estimated at 0.165%, with lethality of 0.04%. The esophagus is the most affected organ, but vascular involvement is often fatal.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available