4.6 Article

Application of Distributed Temperature Sensing for coupled mapping of sedimentation processes and spatio-temporal variability of groundwater discharge in soft-bedded streams

Journal

HYDROLOGICAL PROCESSES
Volume 29, Issue 15, Pages 3408-3422

Publisher

WILEY
DOI: 10.1002/hyp.10455

Keywords

Distributed Temperature Sensing; stream; groundwater discharge

Funding

  1. Centre of Hydrology (HOBE) - Villum Foundation
  2. Spanish Program for Postdoc Mobility of the Ministerio de Educacion
  3. Villum Fonden [00007163] Funding Source: researchfish
  4. Division Of Earth Sciences
  5. Directorate For Geosciences [1440596] Funding Source: National Science Foundation
  6. Division Of Earth Sciences
  7. Directorate For Geosciences [1440506, 1129003, 1128999] Funding Source: National Science Foundation

Ask authors/readers for more resources

The delineation of groundwater discharge areas based on Distributed Temperature Sensing (DTS) data of the streambed can be difficult in soft-bedded streams where sedimentation and scouring processes constantly change the position of the fibre optic cable relative to the streambed. Deposition-induced temperature anomalies resemble the signal of groundwater discharge while scouring will cause the cable to float in the water column and measure stream water temperatures. DTS applied in a looped layout with nine fibre optic cable rows in a 70x5m section of a soft-bedded stream made it possible to detect variability in streambed temperatures between October 2011 and January 2012. Detailed monthly streambed elevation surveys were carried out to monitor the position of the fibre optic cable relative to the streambed and to quantify the effect of sedimentation processes on streambed temperatures. Based on the simultaneous interpretation of streambed temperature and elevation data, a method is proposed to delineate potential high-groundwater discharge areas and identify deposition-induced temperature anomalies in soft-bedded streams. Potential high-discharge sites were detected using as metrics the daily minimum, maximum and mean streambed temperatures as well as the daily amplitude and standard deviation of temperatures. The identified potential high-discharge areas were mostly located near the channel banks, also showing temporal variability because of the scouring and redistribution of streambed sediments, leading to the relocation of pool-riffle sequences. This study also shows that sediment deposits of 0.1m thickness already resulted in an increase in daily minimum streambed temperatures and decrease in daily amplitude and standard deviation. Scouring sites showed lower daily minimum streambed temperatures and higher daily amplitude and standard deviation compared with areas without sedimentation and scouring. As a limitation of the approach, groundwater discharge occurring at depositional and scouring areas cannot be identified by the metrics applied. Copyright (c) 2015 John Wiley & Sons, Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available