4.1 Article

Comparison of intubation conditions with CMAC Miller videolaryngoscope and conventional Miller laryngoscope in lateral position in infants: A prospective randomized trial

Journal

PEDIATRIC ANESTHESIA
Volume 28, Issue 3, Pages 226-230

Publisher

WILEY
DOI: 10.1111/pan.13316

Keywords

airway device; infants; lateral position

Ask authors/readers for more resources

BackgroundEndotracheal intubation in lateral position in infants is a challenge. This difficulty may be surmounted to some extent by using videolaryngoscopes but the routine use of these devices as a tool to secure the airway in lateral position remains unevaluated. Therefore, we conducted a prospective, randomized controlled trial to compare the intubation conditions achieved with the CMAC videolaryngoscope and the Miller Laryngoscope in lateral position in infants. We hypothesized that CMAC videolaryngoscope would provide a better laryngoscopic view and reduce the time to intubation compared to the Miller blade. MethodsSixty-four children aged <1 year, belonging to American Society of Anesthesiologists physical status I-III requiring endotracheal intubation were randomized to undergo tracheal intubation with either the Miller laryngoscope (n = 32) or the CMAC videolaryngoscope (n = 32) in left lateral position. Anesthesia was induced with sevoflurane or thiopentone 5-8 mg/kg IV and atracurium 0.5 mg/kg IV. Total time taken to intubate was assessed as the primary outcome. Laryngoscopic view, intubation difficulty score, success rate of tracheal intubation, number of attempts, maneuvers used, and any airway complications were recorded as secondary outcomes. ResultsThe difference in the mean time to intubate (95% confidence interval) between the Miller and CMAC group was 6.1 (1.7-10.4) seconds. Furthermore, the CMAC videolaryngoscope provided a better laryngoscopic view compared to the conventional Miller blade. In addition, the Intubation Difficulty Scale score was less in the CMAC videolaryngoscope group. ConclusionThe CMAC videolaryngoscope decreases the time taken to intubate and reduces the intubation difficulty when compared to the Miller laryngoscope. Therefore, the CMAC videolaryngoscope may be more useful device when intubating the trachea of infants in the lateral position.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available