4.6 Article

Postocclusive Reactive Hyperemia Occurs in the Rat Retinal Circulation but Not in the Choroid

Journal

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Volume 54, Issue 7, Pages 5123-5131

Publisher

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/iovs.13-12404

Keywords

BOLD; MRI; laser speckle imaging; laser Doppler flowmetry; retinal blood flow; choroidal blood flow; reactive hyperemia

Categories

Funding

  1. NIH/NEI [R01 EY014211, EY018855, EY009702]
  2. MERIT Award from the Department of Veterans Affairs
  3. San Antonio Life Science Institute
  4. CTSA [CTSA-8UL1TR000149]
  5. AHA SWA Predoctoral Fellowship [AHA-13PRE14680087]

Ask authors/readers for more resources

PURPOSE. We tested the hypothesis that retinal blood flow has a postocclusive reactive hyperemia response modulated by occlusion duration and metabolic activity, and that choroidal blood flow does not. METHODS. Anesthetized and paralyzed rats (n = 34) were studied. Retinal and choroidal blood flow was measured by laser speckle imaging and laser Doppler flowmetry, respectively. Blood oxygenation level-dependent functional magnetic resonance imaging (BOLD fMRI) was used to measure changes in relative blood oxygenation of the retinal and choroidal circulations. Transient carotid occlusion was elicited with a hydraulic occluder on the common carotid artery. Several occlusion durations were tested during dark, constant light, and flicker light conditions to modulate metabolic demand. The hyperemia response magnitude was quantified by integrating the area above the blood flow baseline for the 3 minutes after release of the occlusion. RESULTS. Systemic arterial pressure (108.2 +/- 1.4 mm Hg) was unaffected by the carotid occlusions, and was similar among animals and conditions. Retinal blood flow had a reactive hyperemia, but choroidal blood flow did not (e.g., 14 +/- 2%.sec versus 0.5 +/- 4%.sec after 60-second occlusion). The hyperemia magnitude increased as a nonlinear function of occlusion duration and reached a plateau at occlusion durations <60 second. The hyperemia magnitude was not altered by different lighting conditions at occlusion durations of 15 and 60 seconds. BOLD fMRI results were similar to the laser-based blood flow measurements. CONCLUSIONS. The results indicate that metabolic local control has a negligible role in choroidal blood flow regulation and only partially accounts for the blood flow behavior in the retinal circulation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available