4.6 Article

Technical Note: The impact of deformable image registration methods on dose warping

Journal

MEDICAL PHYSICS
Volume 45, Issue 3, Pages 1287-1294

Publisher

WILEY
DOI: 10.1002/mp.12741

Keywords

deformable image registration; adaptive radiotherapy; biomechanical model; dose warping uncertainty

Funding

  1. Elekta RD grant

Ask authors/readers for more resources

PurposeThe purpose of this study was to investigate the clinical-relevant discrepancy between doses warped by pure image based deformable image registration (IM-DIR) and by biomechanical model based DIR (BM-DIR) on intensity-homogeneous organs. Methods and materialsTen patients (5Head&Neck, 5Prostate) were included. A research DIR tool (ADMRIE_v1.12) was utilized for IM-DIR. After IM-DIR, BM-DIR was carried out for organs (parotids, bladder, and rectum) which often encompass sharp dose gradient. Briefly, high-quality tetrahedron meshes were generated and deformable vector fields (DVF) from IM-DIR were interpolated to the surface nodes of the volume meshes as boundary condition. Then, a FEM solver (ABAQUS_v6.14) was used to simulate the displacement of internal nodes, which were then interpolated to image-voxel grids to get the more physically plausible DVF. Both geometrical and subsequent dose warping discrepancies were quantified between the two DIR methods. Target registration discrepancy(TRD) was evaluated to show the geometry difference. The re-calculated doses on second CT were warped to the pre-treatment CT via two DIR. Clinical-relevant dose parameters and passing rate were compared between two types of warped dose. The correlation was evaluated between parotid shrinkage and TRD/dose discrepancy. ResultThe parotid shrunk to 75.7%9% of its pre-treatment volume and the percentage of volume with TRD>1.5mm) was 6.5%+/- 4.7%. The normalized mean-dose difference (NMDD) of IM-DIR and BM-DIR was -0.8%+/- 1.5%, with range (-4.7% to 1.5%). 2mm/2% passing rate was 99.0%+/- 1.4%. A moderate correlation was found between parotid shrinkage and TRD and NMDD. The bladder had a NMDD of -9.9%+/- 9.7%, with BM-DIR warped dose systematically higher. Only minor deviation was observed for rectum NMDD (0.5%+/- 1.1%). ConclusionImpact of DIR method on treatment dose warping is patient and organ-specific. Generally, intensity-homogeneous organs, which undergo larger deformation/shrinkage during treatment and encompass sharp dose gradient, will have greater dose warping uncertainty. For these organs, BM-DIR could be beneficial to the evaluation of DIR/dose-warping uncertainty. (c) 2018 American Association of Physicists in Medicine

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available