4.6 Article

Recommendation of RILEM Technical Committee 250-CSM: Test method for Textile Reinforced Mortar to substrate bond characterization

Journal

MATERIALS AND STRUCTURES
Volume 51, Issue 4, Pages -

Publisher

SPRINGER
DOI: 10.1617/s11527-018-1216-x

Keywords

Single-lap shear bond test; Stress-slip relationship; Fabric Reinforced Mortar (FRM); Fabric Reinforced Cementitious Matrix (FRCM); Steel Reinforced Grout (SRG)

Ask authors/readers for more resources

Textile Reinforced Mortar (TRM), also known as Fabric Reinforced Mortar or Fabric Reinforced Cementitious Matrix, composites are an emerging technology for the external repair and strengthening of existing structures. For most applications, the effectiveness of the TRM reinforcement relies on its bond performance. This recommendation identifies the best practice to characterize the bond behaviour of TRM. A shear bond test method is proposed to determine the peak axial stress (associated with the maximum load that can be transferred from the structural member to the externally bonded TRM reinforcement), the stress-slip relationship and the failure mode that controls the TRM-to-substrate load transfer capacity. Guidelines on specimen manufacturing, experimental setup, test execution, and determination of test results are provided.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available