Application of a new vitamin D blood test on the Emirati population

Journal

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jsbmb.2018.02.003

Keywords

Vitamin 13; Epimers; LC-MS/MS; Emirati population; Vitamin D blood test; Isobars

Funding

  1. United Arab Emirates University (UAEU) [31S213, 31S215]

Ask authors/readers for more resources

Research shows that immunoassay techniques are not the best choice for the estimation of vitamin D in human blood samples. The main reasons are that some immunoassays are not able to distinguish between 25-OHD3 and 25-OHD2 vitamin D metabolites. Furthermore, immunoassays cannot differentiate between 250HD and inactive epimers of vitamin D. Vitamin D epimers and isobars have been known to overlap with the 250HD signals and give false positives when tested. Liquid chromatography tandem-mass spectrometry (LC-MS/MS) can differentiate between 250HD3 and 250HD2. Separating epimers and isobars (which have the same molecular weight) from vitamin D is achieved through chromatographic separation from actual 250HD peaks, although this could also cause inaccuracies in vitamin D measurements. The main aim of this study was to develop and validate an improved LC-MS/MS method (using a Shimadzu 8060 system) that could accurately detect and quantitate up to 10 different metabolites of vitamin D, as well as differentiate the epimers and isobars. The secondary aim was to apply the developed LC-MS/MS method for the accurate measurement of blood vitamin D levels in the Emirati population. The Shimadzu 8060 system was run using positive ion electrospray ionization (ESI) in Dynamic Multiple Reaction Monitoring (DMRM) mode for quantification. The method involved blood sample collection from 80 Emirati volunteers, followed by serum extraction and liquid-liquid extraction. The chromatography column used for the analysis was an Ascentis Express F5. Precursor and product ions were detected using a Shimadzu 8060 LC-MS/MS system, and 10 metabolites of vitamin D were detected and quantified, including epimers and isobars. The method validation showed good sensitivity, recovery, linearity, precision, specificity, and accuracy. Furthermore, the data showed that vitamin D epimer 3-epi-250HD and isobar 7-alpha-hydroxy-4cholesten-3-one (7 alpha C4) accounted for a significant portion of vitamin D results in the Emirati population. We report a more reliable, reproducible, and robust LC-MS/MS method for the accurate detection of 250HD (vitamin D) in the Emirati population. The method has the capacity to detect and separate 10 metabolites of vitamin D as well as separate 250HD from co-eluting epimers and isobars. The method has also been successfully implemented in gauging vitamin D deficiency in the Emirati population. Thus, this improved LC-MS/MS method could prove very useful in accurately estimating the levels of vitamin D in the Emirati population and in further clinical studies.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available