4.5 Article

Glucose-insulin model identified in free-living conditions for hypoglycaemia prevention

Journal

JOURNAL OF PROCESS CONTROL
Volume 64, Issue -, Pages 27-36

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.jprocont.2018.02.003

Keywords

Identification; Validation; Artificial pancreas; Clinical trial; Type 1 diabetes; MPC

Funding

  1. Italian SIR project [RBSI14JYM2 Learn4AP]
  2. Italian project PRIN15: Forgot Diabetes: Adaptive Physiological Artificial Pancreas

Ask authors/readers for more resources

Hypoglycaemia avoidance is one of the main barriers to the optimal management of Type 1 Diabetes (T1D). In order to attenuate the effect of hypoglycaemia, alarm systems support T1D subjects equipped with Continuous Glucose Monitoring (CGM) devices. The development of predictive detection tools for hypoglycaemia and CGM have been accelerated by Artificial Pancreas (AP), a closed-loop systems for automatic blood glucose control in T1D subjects. The methods to generate hypoglycaemia alarms can be divided in two categories: low-threshold detection and prediction. The first notifies the crossing of a critical blood glucose level, while the second predicts this risk in advance and it is typically based on a patient model. Considering the significant inter-patient variability characterizing T1D subjects, patient-tailored models are required. In this regard, different individualization techniques have been proposed showing significant improvements compared to average models. This paper proposes an alarm system based on patient-tailored models obtained through an identification technique that exploits impulse response data collected in silico and that is extended here to be used on free-living data. In particular, the data used in this work derive from a 1 month AP trial performed in free-living conditions. Individualized models obtained with different identification parameters are compared. Independently of the selected parameters, the patient-tailored models show superior predictive performance with respect to the average model used in the Model Predictive Control (MPC) algorithm used in the trial. The best model is used to design an alarm system which shows significant improvements in hypoglycaemia detection in comparison with the safety system used in the trial: true positive are increased by 31% with a decrease of the false positive by 57%. The promising prediction capabilities of the proposed patient-tailored models can be a key ingredient for a new generation of individualised MPC for AP. (C) 2018 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available