4.6 Article

Development, validation and application of a novel HPLC-MS/MS method for the quantification of atorvastatin, bisoprolol and clopidogrel in a large cardiovascular patient cohort

Journal

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume 159, Issue -, Pages 272-281

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2018.06.062

Keywords

Liquid chromatography-mass spectrometry; Assay validation; Atorvastatin; Bisoprolol; Clopidogrel

Funding

  1. NW England MRC Scheme in Clinical Pharmacology and Therapeutics
  2. Newton Fund
  3. UK Academy of Medical Sciences
  4. MRC Centre for Drug Safety Science
  5. NHS Chair of Pharmacogenetics, Department of Health
  6. MRC [MR/M009114/1, MR/L006758/1, G1000417] Funding Source: UKRI

Ask authors/readers for more resources

Cardiovascular disease is a leading cause of morbidity, mortality, and healthcare expenditure worldwide. Importantly, there is interindividual variation in response to cardiovascular medications, leading to variable efficacy and adverse events. Therefore a rapid, selective, sensitive and reproducible multianalyte HPLC-MS/MS assay for the quantification in human plasma of atorvastatin, its major metabolites 2-hydroxyatorvastatin, atorvastatin lactone and 2-hydroxyatorvastatin lactone, plus bisoprolol and clopidogrel-carboxylic acid has been developed, fully validated, and applied to a large patient study. Fifty microliter plasma samples were extracted with a simple protein precipitation procedure involving acetonitrile with acetic acid (0.1%, v/v). Chromatographic separation was via a 2.7 mu m Halo C18 (50 x 2.1 mm ID, 90 angstrom) column and gradient elution at a flow rate of 500 mu L/min consisting of a mobile phase of water (A) and acetonitrile (B), each containing 0.1% formic acid (v/v), over a 6.0 min run time. The six analytes and their corresponding six deuterated internal standards underwent positive ion electrospray ionisation and were detected with multiple reaction monitoring. The developed method was fully validated with acceptable selectivity, carryover, dilution integrity, and within-run and between-run accuracy and precision. Mean extraction recovery for the analytes was 92.7-108.5%, and internal standard-normalised matrix effects had acceptable precision (coefficients of variation 2.2-12.3%). Moreover, all analytes were stable under the tested conditions. Atorvastatin lactone to acid interconversion was assessed and recommendations for its minimisation are made. The validated assay was successfully applied to analyse 1279 samples from 1024 patients recruited to a cardiovascular secondary prevention prospective study. (C) 2018 The Authors. Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available