4.6 Review

The development of neural stimulators: a review of preclinical safety and efficacy studies

Journal

JOURNAL OF NEURAL ENGINEERING
Volume 15, Issue 4, Pages -

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/1741-2552/aac43c

Keywords

neural stimulator; neural prosthesis; preclinical evaluation; safety and efficacy; electrical stimulation; electrodes

Funding

  1. NIDCD [R01DC015031]
  2. NHMRC [APP1122055, APP1113680, APP1120664]
  3. Defense Advanced Research Projects Agency (DARPA) BTO under Dr Doug Weber and Dr Eric Van Gieson through the Space and Naval Warfare Systems Center [N66001-15-2-4060]
  4. Garnett Passe and Rodney Williams Memorial Foundation
  5. Victorian Government through its Operational Infrastructure Support Program
  6. NATIONAL INSTITUTE ON DEAFNESS AND OTHER COMMUNICATION DISORDERS [R01DC015031] Funding Source: NIH RePORTER

Ask authors/readers for more resources

Objective. Given the rapid expansion of the field of neural stimulation and the rigorous regulatory approval requirements required before these devices can be applied clinically, it is important that there is clarity around conducting preclinical safety and efficacy studies required for the development of this technology. Approach. The present review examines basic design principles associated with the development of a safe neural stimulator and describes the suite of preclinical safety studies that need to be considered when taking a device to clinical trial. Main results. Neural stimulators are active implantable devices that provide therapeutic intervention, sensory feedback or improved motor control via electrical stimulation of neural or neuro-muscular tissue in response to trauma or disease. Because of their complexity, regulatory bodies classify these devices in the highest risk category (Class III), and they are therefore required to go through a rigorous regulatory approval process before progressing to market. The successful development of these devices is achieved through close collaboration across disciplines including engineers, scientists and a surgical/clinical team, and the adherence to clear design principles. Preclinical studies form one of several key components in the development pathway from concept to product release of neural stimulators. Importantly, these studies provide iterative feedback in order to optimise the final design of the device. Key components of any preclinical evaluation include: in vitro studies that are focussed on device reliability and include accelerated testing under highly controlled environments; in vivo studies using animal models of the disease or injury in order to assess efficacy and, given an appropriate animal model, the safety of the technology under both passive and electrically active conditions; and human cadaver and ex vivo studies designed to ensure the device's form factor conforms to human anatomy, to optimise the surgical approach and to develop any specialist surgical tooling required. Significance. The pipeline from concept to commercialisation of these devices is long and expensive; careful attention to both device design and its preclinical evaluation will have significant impact on the duration and cost associated with taking a device through to commercialisation. Carefully controlled in vitro and in vivo studies together with ex vivo and human cadaver trials are key components of a thorough preclinical evaluation of any new neural stimulator.