4.7 Article

MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects

Journal

JOURNAL OF MAGNETIC RESONANCE IMAGING
Volume 48, Issue 5, Pages 1288-1296

Publisher

WILEY
DOI: 10.1002/jmri.26000

Keywords

PET; MRI; motion correction; dementia; simultaneous imaging

Funding

  1. National Institutes of Health (NIH) [5R01-EB014894, 5R01-DC014296]
  2. U.S. Department of Defense (DoD) through the National Defense Science & Engineering Graduate Fellowship (NDSEG) Program
  3. National Institute on Deafness and Other Communication Disorders
  4. National Institute of Biomedical Imaging and Bioengineering
  5. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R01EB014894] Funding Source: NIH RePORTER
  6. NATIONAL INSTITUTE ON AGING [R21AG056958] Funding Source: NIH RePORTER
  7. NATIONAL INSTITUTE ON DEAFNESS AND OTHER COMMUNICATION DISORDERS [R01DC014296] Funding Source: NIH RePORTER

Ask authors/readers for more resources

BackgroundPurposeSubject motion in positron emission tomography (PET) studies leads to image blurring and artifacts; simultaneously acquired magnetic resonance imaging (MRI) data provides a means for motion correction (MC) in integrated PET/MRI scanners. To assess the effect of realistic head motion and MR-based MC on static [F-18]-fluorodeoxyglucose (FDG) PET images in dementia patients. Study TypePopulationObservational study. Thirty dementia subjects were recruited. Field Strength/SequenceAssessment3T hybrid PET/MR scanner where EPI-based and T-1-weighted sequences were acquired simultaneously with the PET data. Head motion parameters estimated from high temporal resolution MR volumes were used for PET MC. The MR-based MC method was compared to PET frame-based MC methods in which motion parameters were estimated by coregistering 5-minute frames before and after accounting for the attenuation-emission mismatch. The relative changes in standardized uptake value ratios (SUVRs) between the PET volumes processed with the various MC methods, without MC, and the PET volumes with simulated motion were compared in relevant brain regions. Statistical TestsResultsThe absolute value of the regional SUVR relative change was assessed with pairwise paired t-tests testing at the P=0.05 level, comparing the values obtained through different MR-based MC processing methods as well as across different motion groups. The intraregion voxelwise variability of regional SUVRs obtained through different MR-based MC processing methods was also assessed with pairwise paired t-tests testing at the P=0.05 level. MC had a greater impact on PET data quantification in subjects with larger amplitude motion (higher than 18% in the medial orbitofrontal cortex) and greater changes were generally observed for the MR-based MC method compared to the frame-based methods. Furthermore, a mean relative change of approximate to 4% was observed after MC even at the group level, suggesting the importance of routinely applying this correction. The intraregion voxelwise variability of regional SUVRs was also decreased using MR-based MC. All comparisons were significant at the P=0.05 level. Data ConclusionIncorporating temporally correlated MR data to account for intraframe motion has a positive impact on the FDG PET image quality and data quantification in dementia patients. Level of Evidence: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1288-1296.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available