4.7 Article

Accuracy of High-Throughput Nanofluidic PCR-Based Pneumococcal Serotyping and Quantification Assays Using Sputum Samples for Diagnosing Vaccine Serotype Pneumococcal Pneumonia: Analyses by Composite Diagnostic Standards and Bayesian Latent Class Models

Journal

JOURNAL OF CLINICAL MICROBIOLOGY
Volume 56, Issue 5, Pages -

Publisher

AMER SOC MICROBIOLOGY
DOI: 10.1128/JCM.01874-17

Keywords

Bayesian latent class models; Streptococcus pneumoniae; adult pneumonia; sputum culture; sputum real-time PCR; urinary antigen detection

Categories

Funding

  1. JSPS KAKENHI [25460761]
  2. Pfizer
  3. Nagasaki University
  4. Asahi Kasei Pharma
  5. Taisho Toyama Pharmacy
  6. MSD
  7. Grants-in-Aid for Scientific Research [26293076, 25460761] Funding Source: KAKEN

Ask authors/readers for more resources

The lack of reliable diagnostic tests for detecting vaccine serotype pneumococcal pneumonia (VTPP) remains a challenging issue in pneumococcal vaccine studies. This study assessed the performances of high-throughput nanofluidic PCR-based pneumococcal serotyping and quantification assay methods using sputum samples (the nanofluidic sputum quantitative PCR [Sp-qPCR] assay) to diagnose 13-valent pneumococcal conjugate VTPP compared with the performance of the serotype-specific urinary antigen detection (UAD) assay using urine samples. Adult pneumonia patients from Japan were enrolled in this study between September 2012 and August 2014. Sputum samples were subjected to the nanofluidic Sp-qPCR assay, quantitatively cultured, and serotyped by the Quellung reaction (SpQt). Urine samples were tested by the UAD method. The diagnostic performances of these tests were assessed using composite reference standards and Bayesian latent class models (BLCMs). Among 244 total patients, 27 (11.1%) tested positive with the UAD assay, while 16 (6.6%) and 34 (13.9%) tested positive with the SpQt and nanofluidic SpqPCR assays, respectively, with a cutoff value of >= 10(4) DNA copies/ml, which showed the maximum value of the Youden index. Using BLCMs, the estimated prevalence for VTPP was 12.9%, and the nanofluidic Sp-qPCR assay demonstrated the best performance (sensitivity, 90.2%; specificity, 96.9%), followed by UAD (sensitivity, 75.6%; specificity, 97.9%) and SpQt (sensitivity, 45.8%; specificity, 99.5%). However, when a higher cutoff value of >= 10(7) DNA copies/ml was applied, the performance of UAD became comparable to that of Sp-qPCR. The vaccine serotype-specific pneumococcal DNA load in sputum among UAD-positive patients was 3 logs higher than that among UAD-negative patients (P = 0.036). The nanofluidic Sp-qPCR assay may be accurate and useful for detecting VTPP among adults.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available