4.6 Article

Magnetic sporopollenin-cyanopropyltriethoxysilane-dispersive micro-solid phase extraction coupled with high performance liquid chromatography for the determination of selected non-steroidal anti-inflammatory drugs in water samples

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1532, Issue -, Pages 50-57

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2017.11.059

Keywords

Sporopollenin; Magnetic sporopollenin-cyanopropyltriethoxysilane; Dispersive-micro-solid phase extraction; Non-steroidal anti-inflammatory drugs

Funding

  1. Ministry of Higher Education Malaysia (MOHE) [Q.J130000.2526.12H57]
  2. Ministry of Science, Technology and Innovation Malaysia (MOSTI)

Ask authors/readers for more resources

A facile dispersive-micro-solid phase extraction (D-mu-SPE) method coupled with HPLC for the analysis of selected non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed using a newly prepared magnetic sporopollenin-cyanopropyltriethoxysilane (MS-CNPrTEOS) sorbent. Sporopollenin homogenous microparticles of Lycopodium clavatum spores possessed accessible functional groups that facilitated surface modification. Simple modification was performed by functionalization with 3-cyanopropyltriethoxysilane (CNPrTEOS) and magnetite was introduced onto the biopolymer to simplify the extraction process. MS-CNPrTEOS was identified by infrared spectrometrywhile the morphology and the magnetic property were confirmed by scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM), respectively. To maximize the extraction performance of ketoprofen, ibuprofen, diclofenac and mefenamic acid using the proposed MS-CNPrTEOS, important D-mu-SPE parameters were comprehensively optimized. The optimum extraction conditions were sorbent amount, 40 mg; extraction time, 5 min; desorption time; 5 min; sample volume, 15 mL; sample pH 2.0; and salt addition, 2.5% (w/v). The feasibility of the developed method was evaluated using spiked tap water, lake water, river water and waste water samples. Results showed that ketoprofen and ibuprofen were linear in the range of 1.0-1000 mu g L-1 whilst diclofenac and mefenamic acid were linear in the range 0.8-500 mu g L-1. The results also showed good detection limits for the studied NSAIDs in the range of 0.21-0.51 mu g L-1 and good recoveries for spiked water samples in the range of 85.1-106.4%. The MS-CNPrTEOS proved a promising dispersive sorbent and applicable to facile and rapid assay of NSAIDs in water samples. (C) 2017 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available