4.2 Article

First clinical use of novel ablation catheter incorporating local impedance data

Journal

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY
Volume 29, Issue 9, Pages 1197-1206

Publisher

WILEY
DOI: 10.1111/jce.13654

Keywords

atrial tachycardia; catheter ablation; electrophysiology; impedance; ventricular tachycardia

Funding

  1. IHU LIRYC [ANR-10-IAHU-04]
  2. Boston Scientific

Ask authors/readers for more resources

Introduction: Successful catheter ablation is limited by both poor spatial resolution of abnormal local signals and inability to deliver an effective lesion due to poor tissue contact. We report first worldwide use of the Intellanav MiFi OI catheter (Boston Scientific), providing ultra-high density mapping and incorporating a DirectSense algorithm to measure local tissue impedance (LI). Methods and results: 31 patients (65 +/- 6 years, 20 male) underwent ablation. LI from the catheter, generator impedance (GI) and maximum electrogram amplitude were recorded in the blood pool, and in regions from healthy to dense scar before, during and after ablation. The catheter demonstrated clear nearfield signal where standard bipolar recordings included farfield signal. LI was lower in dense scar than either healthy tissue or blood pool, and demonstrated an exponential relationship with maximum electrogram amplitude. Maximum LI drop on ablation linearly correlated with initial LI. The median LI drop for successful lesions, resulting in lack of local tissue capture, was 16.0 Omega (12.1-19.8 Omega) for LV and 14.6 Omega (10.0-18.3 Omega) for LA, which was larger than for unsuccessful lesions (LV: 9.4 Omega [5.4-15.6 Omega] P = 0.001; LA: 6.8 Omega [4.7-13.0 Omega], P = 0.049). LI percentage drop was also significantly larger for successful than unsuccessful lesions (LV: 17.1 Omega [14.0-19.6 Omega] vs. 10.6 Omega (7.1-16.5 Omega) P = 0.002; LA: 14.2 Omega [10.8-19.5 Omega] vs. 7.5 Omega [5.1-11.0 Omega], P = 0.005). Conclusion: This novel catheter gives reproducible recordings of local impedance, which are dependent on scar level. Absolute LI drop, and also percentage drop, on ablation may give an indication of tissue contact and subsequent effective lesion formation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available