3.8 Proceedings Paper

Comparative study of on-site corrosion monitoring for concrete by different methods

Journal

CIVIL, STRUCTURAL AND ENVIRONMENTAL ENGINEERING, PTS 1-4
Volume 838-841, Issue -, Pages 2066-2070

Publisher

TRANS TECH PUBLICATIONS LTD
DOI: 10.4028/www.scientific.net/AMR.838-841.2066

Keywords

corrosion monitoring; anode ladder system; reference electrode; reinforced concrete

Ask authors/readers for more resources

As one of the key steps in the process of durability design and redesign, corrosion monitoring of reinforcement in concrete is of importance. To ensure the concrete durability of the quay structure, corrosion monitoring systems are utilized in Port Said East Container Terminal - Phase 2, Egypt. Embedded half-cell potential reference electrodes and anode ladder systems were used together. Early stage corrosion monitoring data in a precast slab is presented. Comparison of half-cell potential and anode ladder system data give some comprehensive understanding of the mechanism of the corrosion monitoring.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available