Journal
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
Volume 87, Issue -, Pages 131-153Publisher
ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2017.10.030
Keywords
Heat pumps; Low-GWP refrigerants; Optimization; LCCP; COP
Categories
Ask authors/readers for more resources
An analysis of design configurations is proposed for a 5 kW residential space heating split system comparing several low GWP refrigerants (R32, R290, R1234yf, R1234ze, XL41, XL55) as potential alternatives to the most common refrigerants actually used (R410A, R407C, R134a). By means of an ad-hoc model, the system performance has been estimated for several geometrical configurations among those possible according to the current compressor and heat exchangers technology. The configurations complying with geometric and thermodynamic constraints are discussed in terms of opposing criteria: economic (set-up and total costs), thermodynamic (COP) and environmental ones (LCCP). With R32 it is possible to define design configurations that are able to reach the best energetic performances for fixed set-up costs. In the range of low set-up costs solutions, R32 and R410A design options are able to work with the same performance. Particularly, R32 can reach the minimum LCCP value as propane with 15% lower total costs. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available