4.7 Article

Real time release testing of tablet content and content uniformity

Journal

INTERNATIONAL JOURNAL OF PHARMACEUTICS
Volume 537, Issue 1-2, Pages 183-192

Publisher

ELSEVIER
DOI: 10.1016/j.ijpharm.2017.12.011

Keywords

Real time relea; se testing; Quality by design; Uniformity of dosage units; Content uniformity; Parametric tolerance interval test; Compaction force weight control

Ask authors/readers for more resources

A comprehensive commercial control strategy for tablet content and content uniformity focussed on the unit operation of compression is presented and is proposed to enable real time release for these critical quality attributes. The control strategy is based on process understanding, process control through compaction force weight control on the tablet press, periodic checks of mean and individual tablet weight combined with at-line testing of tablet content by near infrared (NIR). The application of the at-line NIR tablet content method is discussed and an acceptance criteria based on a parametric tolerance interval test (PTIT) is proposed. Sample handling limitations and spectral acquisition time for the NIR content method limit the sample size, however the chosen PTIT assures an appropriate level of batch coverage. Data are presented for ten commercial-scale batches that demonstrates the control strategy delivered the quality standard for content and content uniformity.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available