4.7 Article

Thermohydraulics of a metal foam-filled annulus

Journal

INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Volume 117, Issue -, Pages 95-106

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2017.10.009

Keywords

Metal foam; Heat exchanger; Pressure drop; Temperature distribution; CFD; Thermal entrance length

Funding

  1. University of Queensland
  2. University of Seville
  3. Spanish Government Agency Ministerio de Economia y Competitividad
  4. FEDER Funds [MAT2013-41233-R]

Ask authors/readers for more resources

This paper offers numerical and experimental analysis of forced convection through an annulus filled with aluminium foam. Effects of flow rate and foam pore density on the performance of the heat exchanger were investigated. Specifically, 5 and 20 pore per inch (PPI) aluminium metal foams were tested at three different airflow rates; 20, 85 and 150 standard litre per minute. In parallel, the problem has been simulated numerically. Once validated against experimental data, numerical simulations were conducted to add to the level of details obtained from experiments. The thermal study was done by analysing the temperature field throughout the porous volume and determining the thermal entrance length. This parameter, the thermal entrance length, establishes a reliable design criteria for metal foam-filled heat exchangers, since it marks the length beyond which heat transfer does not significantly increase while the pressure drop keeps growing. (C) 2017 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available