4.7 Article

Numerical investigation of heat transfer characteristics of impinging synthetic jets with different waveforms

Journal

INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Volume 125, Issue -, Pages 1017-1027

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2018.04.120

Keywords

Heat transfer enhancement; Critical Strouhal number; Impinging synthetic jets; Waveform

Funding

  1. National Natural Science Foundation of China [51506162]
  2. Natural Science Basic Research Plan in Shaanxi Province of China [2017JQ5096]

Ask authors/readers for more resources

Synthetic jet, potentially useful in electronic cooling, is numerically studied considering various waveforms for the purpose of heat transfer enhancement and compare to the corresponding steady air jet. In the present study, sinusoidal, rectangular and triangular synthetic jets are applied to a confined two-dimensional slot jet impinging on a heated plate adopting SST/k-omega turbulence model. The jet frequency is varied from 10 to 400 Hz for Reynolds numbers (Re) in the range of 1553-7766 (Strouhal number 0.012 <= St <= 2.4) and jet-to-surface distances ranging from 2 to 8. Generally, the cooling performance is enhanced by increase in Re and with the increase in frequency and H/W, the cooling performance shows a first increase and then decrease trend. Results of simulation indicate that conditions at the turning frequency correspond to critical St = 0.24-0.48 have higher heat transfer rate than other cases at the same Re. When St < 0.06, the heat transfer performance of rectangular jets can be better than the other two jets. When St is close to the critical St, the comparison of heat transfer enhancement is that triangular jets > sinusoidal jets > rectangular jets. Time sequence of streamline and velocity contour image is presented to further explain this phenomenon. Moreover, most conditions show good heat transfer enhancement compare to the corresponding steady jet except conditions in which St is too high (St > 1.2) or H/W is too low, or H/W is too large (H/W = 2 or H/W = 8). The maximum heat transfer enhancement coefficient of synthetic jets is found to be 74.7% higher than that of the corresponding steady jet. (C) 2018 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available