4.1 Article

Implanting a posterior chamber phakic intraocular lens in highly myopic eyes with peripheral primary iris and ciliary body cysts

Journal

EUROPEAN JOURNAL OF OPHTHALMOLOGY
Volume 29, Issue 2, Pages 171-177

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/1120672118766445

Keywords

Implantable collamer lens; primary iris and ciliary body cyst; ultrasonic biological microscope; safety

Categories

Funding

  1. National Natural Science Foundation of China for Young Scholars [81600762]
  2. National Natural Science Foundation of China [81570879, 81770955]
  3. Project of Shanghai Science and Technology [17140902900, 17411950201]

Ask authors/readers for more resources

Purpose: To investigate the safety and efficacy of implanting a posterior chamber implantable collamer lens with a central hole in cases of high myopia with peripheral primary iris or ciliary body cysts. Methods: A total of 37 eyes of 19 patients with primary iris or ciliary body cysts detected by ultrasonic biological microscope were included, with spherical powers of -10.26 +/- 3.28 D and cylinder powers of -1.71 +/- 1.18 D. Each patient received ultrasonic biological microscope and a routine examination before implantation of the implantable collamer lens. A routine postoperative follow-up was performed to observe changes in the iris or ciliary body cyst, ranging from 3 to 18 months. Results: There were no complications. At the last follow-up, 56.8% (21/37) of eyes achieved the same corrected distance visual acuity as their preoperative measurements, 43.2% of eyes were enhanced by >= 1 line, and no patients' corrected distance visual acuity declined. The efficacy index and safety index were 0.95 and 1.11, respectively. After 18 months, 66.7% of the spherical equivalents were between +/- 0.5 D with 100% between +/- 1.0 D. The postoperative mean spherical equivalents at 1, 3, 6, 12, and 18 months were -0.45 +/- 0.31 D, -0.39 +/- 0.29 D, -0.36 +/- 0.30 D, -0.39 +/- 0.38 D, and -0.48 +/- 0.23 D (p = 0.789). The vaults were 516 +/- 140, 548 +/- 124, 498 +/- 133, 582 +/- 161, and 557 +/- 110 mu m (p = 0.355). There were no changes in size (p > 0.05), number, or position of the iris or ciliary body cysts. Conclusion: Implantable collamer lens implantation is safe and effective for highly myopic patients with peripheral primary iris and ciliary body cysts. The cysts did not change after operation in this study.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available