4.7 Article

NEW CONSTRAINTS ON COSMIC POLARIZATION ROTATION FROM THE ACTPol COSMIC MICROWAVE BACKGROUND B-MODE POLARIZATION OBSERVATION AND THE BICEP2 CONSTRAINT UPDATE

Journal

ASTROPHYSICAL JOURNAL
Volume 805, Issue 2, Pages -

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/0004-637X/805/2/107

Keywords

cosmic background radiation; cosmological parameters; early universe; gravitation; inflation; polarization

Funding

  1. NSFC [11275035]
  2. Fundamental Research Funds for the Central Universities [DUT13LK01]
  3. Open Project Program of State Key Loboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences [Y4KF101CJ1]

Ask authors/readers for more resources

Recently, ACTPol measured the cosmic microwave background (CMB) B-mode and E-mode polarizations and obtained TE, EE, BB, TB, and EB power spectra in the multipole range 225-8725. In our previous paper (Paper I), we jointly analyzed the results of three experiments on the CMB B-mode polarization-SPTpol, POLARBEAR, and BICEP2-to include in the model, in addition to the gravitational lensing and inflationary gravitational waves components, the fluctuation effects induced by cosmic polarization rotation (CPR) if it exists within the upper limits at the time. In this paper, we fit both the mean CPR angle [alpha] and its fluctuation [delta alpha(2)] from the new ACTPol data, and update our fitting of CPR fluctuations using the BICEP2 data taking the new Planck dust measurement results into consideration. We follow the same method used in Paper I. The mean CPR angle is constrained from the EB correlation power spectra to |[alpha]| < 14 mrad (0.degrees 8) and the fluctuation (rms) is constrained from the BB correlation power spectra to [delta alpha(2)](1/2) < 29.3 mrad (1.degrees 68). Assuming that the polarization angle of Tau A does not change from 89.2 to 146 GHz, the ACTPol data give [alpha] = 1.0 +/- 0.degrees 63. These results suggest that the inclusion of the present ACTPol data is consistent with no CPR detection. Using the new Planck dust measurement, we update our fits of the BICEP2 CPR fluctuation constraint to be 32.8 mrad (1.degrees 88). The joint ACTPol-BICEP2-POLARBEAR CPR fluctuation constraint is 23.7 mrad (1.degrees 36).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available