4.7 Article

AN ELECTRON-TRACKING COMPTON TELESCOPE FOR A SURVEY OF THE DEEP UNIVERSE BY MeV GAMMA-RAYS

Journal

ASTROPHYSICAL JOURNAL
Volume 810, Issue 1, Pages -

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/0004-637X/810/1/28

Keywords

gamma-ray burst: general; instrumentation: detectors; nuclear reactions, nucleosynthesis, abundances; supernovae: general; techniques: imaging spectroscopy

Funding

  1. Japan Society for the Promotion of Science (JSPS) [21224005, 20244026, 23654067, 25610042]
  2. Ministry of Education, Culture, Sports, Science and Technology (MEXT) of Japan
  3. Solar-Terrestrial Environment Laboratory, Nagoya University
  4. National Institute of Polar Research [23-3]
  5. [09J01029]
  6. [11J00606]
  7. [13J01213]
  8. Grants-in-Aid for Scientific Research [13J01213, 15K17608, 21224005, 20244026, 25610042, 23654067] Funding Source: KAKEN

Ask authors/readers for more resources

Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which originate from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected a mere similar to 30 persistent sources. It is in stark contrast with the similar to 2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be helpful to reduce the background under conditions similar to those in space. Accordingly, the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below 1 x 10(-12) erg cm(-2) s(-1) at 1 MeV.