4.6 Article

Normal Perceptual Sensitivity Arising From Weakly Reflective Cone Photoreceptors

Journal

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Volume 56, Issue 8, Pages 4431-4438

Publisher

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/iovs.15-16547

Keywords

adaptive optics; cone sensitivity; retinal imaging

Categories

Funding

  1. NEI NIH HHS [EY014375, EY022412, EY007043, L30 EY021930, EY021642, R01 EY014375, T32 EY007043, R21 EY021642, R01 EY023591, F32 EY007043, R01 EY023581, P30 EY003039, EY003039, K23 EY022412, EY023591, EY023581] Funding Source: Medline
  2. NHLBI NIH HHS [T35HL07473, T35 HL007473] Funding Source: Medline

Ask authors/readers for more resources

PURPOSE. To determine the light sensitivity of poorly reflective cones observed in retinas of normal subjects, and to establish a relationship between cone reflectivity and perceptual threshold. METHODS. Five subjects (four male, one female) with normal vision were imaged longitudinally (7-26 imaging sessions, representing 82-896 days) using adaptive optics scanning laser ophthalmoscopy (AOSLO) to monitor cone reflectance. Ten cones with unusually low reflectivity, as well as 10 normally reflective cones serving as controls, were targeted for perceptual testing. Cone-sized stimuli were delivered to the targeted cones and luminance increment thresholds were quantified. Thresholds were measured three to five times per session for each cone in the 10 pairs, all located 2.2 to 3.3 degrees from the center of gaze. RESULTS. Compared with other cones in the same retinal area, three of 10 monitored dark cones were persistently poorly reflective, while seven occasionally manifested normal reflectance. Tested psychophysically, all 10 dark cones had thresholds comparable with those from normally reflecting cones measured concurrently (P = 0.49). The variation observed in dark cone thresholds also matched the wide variation seen in a large population (n = 56 cone pairs, six subjects) of normal cones; in the latter, no correlation was found between cone reflectivity and threshold (P = 0.0502). CONCLUSIONS. Low cone reflectance cannot be used as a reliable indicator of cone sensitivity to light in normal retinas. To improve assessment of early retinal pathology, other diagnostic criteria should be employed along with imaging and cone-based microperimetry.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available