4.3 Article

Reflector-guided breast tumor localization versus wire localization for lumpectomies: A comparison of surgical outcomes

Journal

CLINICAL IMAGING
Volume 47, Issue -, Pages 14-17

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.clinimag.2017.07.020

Keywords

Breast cancer; Tumor localization

Ask authors/readers for more resources

Purpose: To compare surgical outcomes of SAVI scour reflector localization (SSL) versus wire localization (WL) for breast tumors. Methods: Retrospective review of 42 SSL cases and 42 WL cases. WL patients were consecutively matched for clinical-pathologic features. Final surgical outcome measures were tumor specimen volume, margin status, and re-excision rates. Results: No significant differences were present in median specimen volumes (SSL-15.2 cm(3) vs. WL-16.3 cm(3)), positive margin rate (SSL-9.5% vs. WL-7.1%), close margin rate (SSL-7.1% vs. WL-11.9%) or re-excision rate (SSL-7.1% vs. WL-9.5%). Conclusion: SSL is an acceptable alternative to WL with no significant differences in surgical outcomes. (C) 2017 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available