4.7 Article

Clinical Assay for AFP-L3 by Using Multiple Reaction Monitoring-Mass Spectrometry for Diagnosing Hepatocellular Carcinoma

Journal

CLINICAL CHEMISTRY
Volume 64, Issue 8, Pages 1230-1238

Publisher

AMER ASSOC CLINICAL CHEMISTRY
DOI: 10.1373/clinchem.2018.289702

Keywords

-

Funding

  1. Collaborative Genome Program for Fostering New Post-Genome Industry, a National Research Foundation [NRF-2017M3C9A5031597, 2011-0030740]
  2. Industrial Strategic Technology Development Program [10079271]
  3. Korea Health Technology RD Project [HI14C2640]

Ask authors/readers for more resources

BACKGROUND: Lens culinaris agglutinin-reactive fraction of alpha-fetoprotein (AFP-L3) is a serum biomarker for hepatocellular carcinoma (HCC). AFP-L3 is typically measured by liquid-phase binding assay (LiBA). However, LiBA does not always reflect AFP-L3 concentrations because of its low analytical sensitivity. Thus, we aimed to develop an analytically sensitive multiple reaction monitoring-mass spectrometry (MRM-MS) assay to quantify AFP-L3 in serum. METHODS: The assay entailed the addition of a stable isotope-labeled internal standard protein analog, the enrichment of AFP using a monoclonal antibody, the fractionation of AFP-L3 using L. culinaris agglutinin lectin, deglycosylation, trypsin digestion, online desalting, and MRM-MS analysis. The performance of the MRM-MS assay was compared with that of LiBA in 400 human serum samples (100 chronic hepatitis, 100 liver cirrhosis, and 200 HCC). Integrated multinational guidelines were followed to validate the assay for clinical implementation. RESULTS: The lower limit of quantification of the MRM-MS assay (0.051 ng/mL) for AFP-L3 was less than that of LiBA (0.300 ng/mL). Thus, AFP-L3, which was not observed by LiBA in HCC samples (n = 39), was detected by the MRM-MS assay, improving the clinical value of AFP-L3 as a biomarker by switching to a more analytical sensitive platform. The method was validated, meeting all the criteria in integrated multinational guidelines. CONCLUSIONS: Because of the lower incidence of falsenegative findings, the MRM-MS assay is more suitable than LiBA for early detection of HCC. (C) 2018 American Association for Clinical Chemistry

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available