4.3 Article

Catheter-Based Measurements of Absolute Coronary Blood Flow and Microvascular Resistance Feasibility, Safety, and Reproducibility in Humans

Journal

CIRCULATION-CARDIOVASCULAR INTERVENTIONS
Volume 11, Issue 3, Pages -

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCINTERVENTIONS.117.006194

Keywords

coronary angiography; fractional flow reserve; microvascular angina; microvessels; myocardial; reproducibility of results; temperature; thermodilution

Funding

  1. European Association of Percutaneous Cardiovascular Interventions
  2. Hellenic Cardiological Society
  3. Swiss National Science Foundation
  4. CardioPaTh Ph.D. program

Ask authors/readers for more resources

Background-The principle of continuous thermodilution can be used to calculate absolute coronary blood flow and microvascular resistance (R). The aim of the study is to explore the safety, feasibility, and reproducibility of coronary blood flow and R measurements as measured by continuous thermodilution in humans. Methods and Results-Absolute coronary flow and R can be calculated by thermodilution by infusing saline at room temperature through a dedicated monorail catheter. The temperature of saline as it enters the vessel, the temperature of blood and saline mixed in the distal part of the vessel, and the distal coronary pressure were measured by a pressure/temperature sensor-tipped guidewire. The feasibility and safety of the method were tested in 135 patients who were referred for coronary angiography. No significant adverse events were observed; in 11 (8.1%) patients, bradycardia and concomitant atrioventricular block appeared transiently and were reversed immediately on interruption of the infusion. The reproducibility of measurements was tested in a subgroup of 80 patients (129 arteries). Duplicate measurements had a strong correlation both for coronary blood flow (rho=0.841, P<0.001; intraclass correlation coefficient=0.89, P<0.001) and R (rho=0.780, P<0.001; intraclass correlation coefficient=0.89, P<0.001). In Bland-Altman plots, there was no significant bias or asymmetry. Conclusions-Absolute coronary blood flow (in L/min) and R (in mm Hg/L/min or Wood units) can be safely and reproducibly measured with continuous thermodilution. This approach constitutes a new opportunity for the study of the coronary microcirculation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available