4.7 Article

Silver nanoparticles modified two-dimensional transition metal carbides as nanocarriers to fabricate acetycholinesterase-based electrochemical biosensor

Journal

CHEMICAL ENGINEERING JOURNAL
Volume 339, Issue -, Pages 547-556

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.cej.2018.01.111

Keywords

MXene; Ag@Ti3C2Tx nanocomposites; Acetylcholinesterase biosensor; Malathion

Funding

  1. National Nature Science Foundation of China [21576068, 21276060, 21276062, 21306039]
  2. Natural Science Foundation of Tianjin [16JCYBJC19800]
  3. Natural Science Foundation of Hebei Province [B2015202082, B2016202027, B2017202056]
  4. Program for Top 100 Innovative Talents in Colleges and Universities of Hebei Province [SLRC2017029]
  5. Hebei High Level Personnel of Support Program [A2016002027]
  6. Graduate Innovation Support Program in Hebei Province [CXZZSS2017024]

Ask authors/readers for more resources

The Ag@Ti3C2Tx nanocomposites were successfully synthesized via a reduction process by using the transition metal carbides (MXenes) as reducing agent and support. The obtained Ag@Ti3C2Tx nanocomposites can be deemed as a promising material in electrochemical fields. Using the Ag@Ti3C2Tx nanocomposites as nanocarriers, an acetylcholinesterase (AChE) biosensor was fabricated through drop-casting method for electrochemical detection of organophosphate pesticides (OPs), via enzymatic inhibition pathway. The proposed biosensor that combined the unique electrocatalytic properties and synergistic effects between Ti3C2Tx nanosheets and Ag nanoparticles not only facilitated the electron transfer, but also enlarged the available surface area for OPs detection. The electrochemical behaviors of the fabricated AChE biosensor were performed on an electrochemical workstation. Under optimum conditions, the AChE biosensor showed favorable affinity to acetylthiocholine chloride (ATCl) and the corresponding apparent Michaelis-Menten constant (Km app) value was 257.67 mu M. The AChE biosensor detected malathion in the linear range from 10(-14) to 10(-8) M. In addition, the developed AChE biosensor exhibited satisfactory selectivity, acceptable reproducibility and good stability, which could be used for determination of malathion in a real sample (tap water) with satisfactory recoveries.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available