Diffusion-weighted magnetic resonance imaging in cancer: Reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility

Journal

WORLD JOURNAL OF RADIOLOGY
Volume 8, Issue 1, Pages 21-49

Publisher

BAISHIDENG PUBLISHING GROUP INC
DOI: 10.4329/wjr.v8.i1.21

Keywords

Diffusion-weighted magnetic resonance imaging; Apparent diffusion coefficient reproducibility; Apparent diffusion coefficient; Cancer imaging; Extracranial organs

Ask authors/readers for more resources

There is considerable disparity in the published apparent diffusion coefficient (ADC) values across different anatomies. Institutions are increasingly assessing repeatability and reproducibility of the derived ADC to determine its variation, which could potentially be used as an indicator in determining tumour aggressiveness or assessing tumour response. In this manuscript, a review of selected articles published to date in healthy extracranial body diffusion-weighted magnetic resonance imaging is presented, detailing reported ADC values and discussing their variation across different studies. In total 115 studies were selected including 28 for liver parenchyma, 15 for kidney (renal parenchyma), 14 for spleen, 13 for pancreatic body, 6 for gallbladder, 13 for prostate, 13 for uterus (endometrium, myometrium, cervix) and 13 for fibroglandular breast tissue. Median ADC values in selected studies were found to be 1.28 x 10(-3) mm(2)/s in liver, 1.94 x 10(-3) mm(2)/s in kidney, 1.60 x 10(-3) mm(2)/s in pancreatic body, 0.85 x 10(-3) mm(2)/s in spleen, 2.73 x 10(-3) mm(2)/s in gallbladder, 1.64 x 10(-3) mm(2)/s and 1.31 x 10(-3) mm(2)/s in prostate peripheral zone and central gland respectively (combined median value of 1.54x10(-3) mm(2)/s), 1.44 x 10(-3) mm(2)/s in endometrium, 1.53 x 10(-3) mm(2)/s in myometrium, 1.71 x 10(-3) mm(2)/s in cervix and 1.92 x 10(-3) mm(2)/s in breast. In addition, six phantom studies and thirteen in vivo studies were summarized to compare repeatability and reproducibility of the measured ADC. All selected phantom studies demonstrated lower intra-scanner and inter-scanner variation compared to in vivo studies. Based on the findings of this manuscript, it is recommended that protocols need to be optimised for the body part studied and that system-induced variability must be established using a standardized phantom in any clinical study. Reproducibility of the measured ADC must also be assessed in a volunteer population, as variations are far more significant in vivo compared with phantom studies.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available