4.7 Article

Reliable determination of chemical state in x-ray photoelectron spectroscopy based on sample-work-function referencing to adventitious carbon: Resolving the myth of apparent constant binding energy of the C 1s peak

Journal

APPLIED SURFACE SCIENCE
Volume 451, Issue -, Pages 99-103

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.apsusc.2018.04.226

Keywords

XPS; Surface chemistry; Adventitious carbon; Binding energy reference; Work function

Funding

  1. Alice Wallenberg Foundation [KAW2016.0358]
  2. VINN Excellence Center Functional Nanoscale Materials (FunMat-2) [2016-05156]
  3. Stiftelsen Aforsk [16-359]
  4. Carl Tryggers Stiftelse [CTS 17:166]

Ask authors/readers for more resources

The accuracy of chemical-state determination by x-ray photoelectron spectroscopy (XPS) used in contemporary advanced materials research relies on a trustworthy binding energy (BE) referencing method. The C 1s peak corresponding to C-C/C-H bonds of adventitious carbon (AdC), present on a majority of air-exposed samples, is most commonly employed for this purpose, irrespective of whether samples are electrically conducting or not. Contrary to conventional practice, which takes the BE of C 1s peak of AdC as a constant, we find that the C 1s peak position E-B(F) varies over an alarmingly large range, from 284.08 to 286.74 eV, depending on the substrate, for nearly a hundred predominantly thin-film samples comprising metals, nitrides, carbides, borides, oxides, and oxynitrides. Our consistent measurements also show that, independent of materials system, E-B(F) of the C 1s peak is closely correlated to the sample work function phi(SA),such that the sum E-B(F) thorn /SA is constant, indicating that the electronic levels of the AdC layer align to the vacuum level, rather than to the Fermi level as commonly assumed. This phenomenon can be understood given that the AdC layer is not an inherent part of the analyzed sample and that the interaction to the substrate is weak, showing in that a common Fermi level is not established at the interface. Thus, a straightforward complementary measurement of /SA enables using the C 1s peak of AdC for the purpose of BE-scale calibration for samples exhibiting decent electrical conductivity. This new practice resolves problems associated with the conventional method and allows for more reliable bonding assignments. It is thus advisable that both ASTM and ISO XPS referencing guides relying on the use of AdC should be reviewed. (C) 2018 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available