Journal
APPLIED ERGONOMICS
Volume 70, Issue -, Pages 148-155Publisher
ELSEVIER SCI LTD
DOI: 10.1016/j.apergo.2018.02.009
Keywords
-
Categories
Funding
- European Commission under the Robomate FP7 project [608979]
Ask authors/readers for more resources
The aim of this study was to evaluate the effect of a passive upper body exoskeleton on muscle activity, perceived musculoskeletal effort, local perceived pressure and subjective usability for a static overhead task. Eight participants (4 male, 4 female) held a load (0 kg and 2 kg) three times overhead for a duration of 30 s each, both with and without the exoskeleton. Muscle activity was significantly reduced for the Biceps Brachii (49%) and Medial Deltoid (62%) by the device for the 2 kg load. Perceived effort of the arms was significantly lower with the device for the 2 kg load (41%). The device did not have a significant effect on trunk or leg muscle activity (for the 2 kg load) or perceived effort. Local perceived pressure was rated below 2 (low pressure levels) for all contact areas assessed. Half of the participants rated the device usability as acceptable. The exoskeleton reduced muscle activity and perceived effort by the arms, and had no significant negative effect on the trunk and lower body with regards to muscle activity, perceived effort and localised discomfort.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available