4.8 Article

Point-of-Care Determination of Acetaminophen Levels with Multi-Hydrogen Bond Manipulated Single-Molecule Recognition (eMuHSiR)

Journal

ANALYTICAL CHEMISTRY
Volume 90, Issue 7, Pages 4733-4740

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.7b05361

Keywords

-

Funding

  1. NIMHD-RCMI [5G12MD007595]
  2. NIGMS-BUILD [8UL1GM118967]
  3. NIH-RTRN [U54MD008149]
  4. National Science Foundation [HRD-1700429]
  5. NSF HBCU-UP program [HRD-1505219]
  6. NIH R15 program [1R15GM113193-01]
  7. NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES [UL1GM118967] Funding Source: NIH RePORTER
  8. National Institute on Minority Health and Health Disparities [G12MD007595, U54MD008149] Funding Source: NIH RePORTER

Ask authors/readers for more resources

This work aims to face the challenge of monitoring small molecule drugs accurately and rapidly for point-of-care (POC) diagnosis in current clinical settings. Overdose of acetaminophen (AP), a commonly used over the counter (OTC) analgesic drug, has been determined to be a major cause of acute liver failure in the US and the UK. However, there is no rapid and accurate detection method available for this drug in the emergency room. The present study examined an AP sensing strategy that relies on a previously unexplored strong interaction between AP and the arginine (Arg) molecule. It was found that as many as 4 hydrogen bonds can be formed between one Arg molecule and one AP molecule. By taking advantages of this structural selectivity and high tenability of hydrogen bonds, Arg, immobilized a graphene surface via electrostatic interactions, was utilized to structurally capture AP. Interestingly, bonded AP still remained the perfect electrochemical activities. The extent of Arg-AP bonds was quantified using a newly designed electrochemical (EC) sensor. To verify the feasibility of this novel assay, based on multi-hydrogen bond manipulated single-molecule recognition (eMuHSiR), both pharmaceutical and serum sample were examined. In commercial tablet measurement, no significant difference was seen between the results of eMuHSiR and other standard methods. For measuring AP concentration in the mice blood, the substances in serum, such as sugars and fats, would not bring any interference to the eMuHSiR in a wide concentration range. This eMuHSiR method opens the way for future development of small molecule detection for the POC testing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available