4.7 Article

Magnetic ionic liquids as versatile extraction phases for the rapid determination of estrogens in human urine by dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 410, Issue 19, Pages 4689-4699

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-017-0823-7

Keywords

Magnetic ionic liquids; Sample preparation; Urine; Biological samples

Funding

  1. Chemical Measurement and Imaging Program at the National Science Foundation [CHE-1709372]
  2. Brazilian Government Agency Conselho Nacional de Desenvolvimento Cientifico e Tecnologioco (CNPq)
  3. Fundacao de Amparo a Pesquisa do Estado de Santa Catarina (FAPESC)
  4. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)

Ask authors/readers for more resources

In this study, a rapid and straightforward approach based on magnetic ionic liquids (MIL) as extraction phases and dispersive liquid-liquid microextraction (DLLME) was developed to analyze the hormones estriol, 17-beta-estradiol, 17-alpha-ethynylestradiol, and estrone in human urine samples. This is the first report of an application of manganese-based MILs compatible with HPLC to extract compounds of biological interest from urine samples. The hydrophobic MILs trihexyltetradecylphosphonium tetrachloromanganate (II) ([P-6,P-6,P-6,P-14 (+)](2)[MnCl4 (2-)]) and aliquat tetrachloromanganate (II) ([Aliquat(+)](2)[MnCl4 (2-)]) were employed and the optimized extraction conditions were comprised of 5 mg of MIL ([P-6,P-6,P-6,P-14 (+)](2)[MnCl4 (2-)]), 5 mu L of methanol (MeOH) as disperser solvent, and an extraction time of 90 s at sample pH 6. The analytical parameters of merit were determined under optimized conditions and very satisfactory results were achieved, with LODs of 2 ng mL(-1) for all analytes, determination coefficients (R (2)) ranging from 0.9949 for 17-beta-estradiol to 0.9998 for estrone. In addition, good results of method precision were achieved with the intraday (n = 3) varying from 4.7% for 17-beta-estradiol to 19.5% for estriol (both at 5 ng mL(-1)) and interday precision (evaluated at 100 ng mL(-1)) ranging from 11.4% for estrone to 17.7% for 17-alpha-ethynylestradiol and analyte relative recovery evaluated in three real samples ranged from 67.5 to 115.6%. The proposed DLLME/MIL-based approach allowed for a reliable, environmentally friendly and high-throughput methodology with no need for a centrifugation step.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available