4.7 Article

Evaluating drywells for stormwater management and enhanced aquifer recharge

Journal

ADVANCES IN WATER RESOURCES
Volume 116, Issue -, Pages 167-177

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.advwatres.2018.04.003

Keywords

Drywell; HYDRUS (2D/3D); Falling head; Inverse simulation; Hydraulic properties; In situ

Funding

  1. U.S. Environmental Protection Agency (US EPA) through United States Department of Agriculture [EPA DW-012-92465401, ARS 60-2022-7-002]

Ask authors/readers for more resources

Drywells are increasingly used for stormwater management and enhanced aquifer recharge, but only limited research has quantitatively determined the performance of drywells. Numerical and field scale experiments were, therefore, conducted to improve our understanding and ability to characterize the drywell behavior. In particular, HYDRUS (2D/3D) was modified to simulate transient head boundary conditions for the complex geometry of the Maxwell Type IV drywell; i.e., a sediment chamber, an overflow pipe, and the variable geometry and storage of the drywell system with depth. Falling-head infiltration experiments were conducted on drywells located at the National Training Center in Fort Irwin, California (CA) and a commercial complex in Torrance, CA to determine in situ soil hydraulic properties (the saturated hydraulic conductivity, K-s and the retention curve shape parameter, alpha) for an equivalent uniform soil profile by inverse parameter optimization. A good agreement between the observed and simulated water heights in wells was obtained for both sites as indicated by the coefficient of determination 0.95-0.99-%, unique parameter fits, and small standard errors. Fort Irwin and Torrance drywells had very distinctive soil hydraulic characteristics. The fitted value of K-s=1.01 x 10(-3) m min(-1) at the Torrance drywell was consistent with the sandy soil texture at this site and the default value for sand in the HYDRUS soil catalog. The drywell with this K-s = 1.01 x 10(-3) m min(-1) could easily infiltrate predicted surface runoff from a design rain event (similar to 51.3 m(3)) within 5760 min (4 d). In contrast, the fitted value of K-s=2.25 x 10(-6) m min(-1) at Fort Irwin was very low compared to the Torrance drywell and more than an order of magnitude smaller than the default value reported in the HYDRUS soil catalog for sandy clay loam at this site, likely due to clogging. These experiments and simulations provide useful information to characterize effective soil hydraulic properties in situ, and to improve the design of drywells for enhanced recharge.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available