4.8 Article

Palladium Supported on an Amphiphilic Triazine-Urea-Functionalized Porous Organic Polymer as a Highly Efficient Electrocatalyst for Electrochemical Sensing of Rutin in Human Plasma

Journal

ACS APPLIED MATERIALS & INTERFACES
Volume 10, Issue 23, Pages 19554-19563

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsami.8b00579

Keywords

electrochemical sensor; rutin detection; Pd nanoparticles; cyclic voltammetry; porous organic polymers

Funding

  1. National Research Foundation - Ministry of Science, ICT and Future Planning of Korea [2017M2A2A6A01020938, 2018R1A2B2006094]
  2. R&D Convergence Program of the National Research Council of Science and Technology [CAP-15-02-KBSI]
  3. National Research Foundation of Korea [2018R1A2B2006094] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

Metal nanoparticle-containing porous organic polymers have gained great interest in chemical and pharmaceutical applications owing to their high reactivity and good recyclability. In the present work, a palladium nanoparticle-decorated triazine-urea-based porous organic polymer (Pd@TU-POP) was designed and synthesized using 1,3-bis(4-aminophenyl)urea with cyanuric chloride and palladium acetate. The porous structure and physicochemical properties of the electrode material PdpTU-POP were observed using a range of standard techniques. The Pd@TU-POP material on the electrode surface showed superior sensing ability for rutin (RT) because the Pd dispersion facilitated the electrocatalytic performance of TU-POP by reducing the overpotential of RT oxidation dramatically and improving the stability significantly. Furthermore, TU-POP provides excellent structural features for loading Pd nanoparticles, and the resulting Pd@TU-POP exhibited enhanced electron transfer and outstanding sensing capability in a linear range between 2 and 200 pM having a low detection value of 5.92 x 10(-12) M (S/N = 3). The abundant porous structure of Pd@TU-POP not only provides electron transport channels for RT diffusion but also offers a facile route for quantification sensing of RT with satisfactory recoveries in aqueous electrolyte containing human plasma and red wine. These data reveal that the synthetic Pd@TU-POP is an excellent potential platform for the detection of RT in biological samples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available