The concentration gradient of K+ across the cell membrane of a neuron determines its resting potential and cell excitability. During neurotransmission, the efflux of K+ from the cell via various channels will not only decrease the intracellular K+ content but also elevate the extracellular IC-concentration. However, it is not clear to what extent this change could be. In this study, we developed a multiple-parallel-connected silicon nanowire field-effect transistor (SiNW-FET) modified with K+-specific DNA-aptamers (aptamer/SiNW-FET) for the real-time detection of the r efflux from cultured cortical neurons. The aptamer/SiNW-FET showed an association constant of (2.18 +/- 0.44) x 10(6) M-1 against K+ and an either less or negligible response to other alkali metal ions. The alpha-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA) stimulation induced an outward current and hyperpolarized the membrane potential in a whole-cell patched neuron under a Na+/K+-free buffer. When neurons were placed atop the aptamer/ SiNW-FET in a Na+/K+-free buffer, AMPA (13 mu M) stimulation elevated the extracellular K+ concentration to similar to 800 nM, which is greatly reduced by 6,7-dinitroquinoxaline-2,3-dione, an AMPA receptor antagonist. The EC50 of AMPA in elevating the extracellular K+ concentration was 10.3 mu M. By stimulating the neurons with AMPA under a normal physiological buffer, the K+ concentration in the isolated cytosolic fraction was decreased by 75%. These experiments demonstrate that the aptamer/SiNW-FET is sensitive for detecting cations and the K+ concentrations inside and outside the neurons could be greatly changed to modulate the neuron excitability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available