4.7 Article

Validation of a method to differentiate arterial and venous vessels in CT perfusion data using linear combinations of quantitative time-density curve characteristics

Journal

EUROPEAN RADIOLOGY
Volume 25, Issue 10, Pages 2937-2944

Publisher

SPRINGER
DOI: 10.1007/s00330-015-3709-0

Keywords

X-ray computed tomography; Diagnostic imaging; Angiography; Discriminant analysis; Brain

Ask authors/readers for more resources

We aimed to develop and evaluate a new method that reliably differentiates between cerebral arteries and veins using voxel-wise CT-perfusion-derived parameters. Fourteen consecutive patients with suspected stroke but without pathological findings were examined on a multi-detector CT system: 32 dynamic phases (a dagger t = 1.5 s) during application of 35 mL iomeprol-350 were acquired at 80 kV/200mAs. Three hemodynamic parameters were calculated for 18 arterial and venous vessel segments: A (maximum of the time-density-curve), T (time-to-peak), and W (full-width-at-half-maximum). Using receiver operator characteristic (ROC) curve analysis and Fisher's linear discriminant analysis (FLDA), the performance of every classifier (A, T, W) and of all linear combinations for the differentiation of arterial and venous vessels was determined. A maximum area under the ROC-curve (AUC) of 0.945 (accuracy = 86.8 %) was obtained using the FLDA combination of A&T or the triplet FLDA of A&T&W for the classification of venous and arterial vessels. The best single parameter was T with an AUC of 0.871 (accuracy = 79.0 %), which performed significantly worse than the combination A&T (p < 0.001). Arteries and veins can be accurately differentiated based on dynamic CT perfusion data using the maximum of the time-density curve, its time-to-peak, its width, and FLDA combinations of these parameters, which yield accuracies up to 87 %. For classification of cerebral vasculature, time-to-peak has the best single-parameter accuracy. Fisher's linear discriminant analysis improves the performance of the individual classifiers. Combining signal maximum and time-to-peak parameters significantly increased the classifying potential. Pre-processing of time-density-curves by Gaussian filtering or fitting can improve diagnostic accuracy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available