4.5 Article

Diagnostic Performance of 18F-FDG-PET/CT in Vascular Graft Infections

Journal

Publisher

W B SAUNDERS CO LTD
DOI: 10.1016/j.ejvs.2014.12.024

Keywords

Positron emission tomography/computed tomography; Graft infection; Fludeoxy glucose

Funding

  1. Vascular graft Cohort Study (VASGRA) - Swiss National Science Foundation [320030_144277/1]
  2. Promedica Foundation [1080/A]
  3. Vontobel Foundation
  4. Rozalia Foundation
  5. Swiss National Science Foundation (SNF) [320030_144277] Funding Source: Swiss National Science Foundation (SNF)

Ask authors/readers for more resources

Objective: The aim of this study was to evaluate the diagnostic accuracy of positron emission tomography/computed tomography with F-18-fludeoxyglucose (FDG-PET/CT) in a population with suspected graft infection and to validate a new diagnostic imaging score for FDG-PET/CT. Methods: This was a prospective cohort study. FDG-PET/CT was performed prospectively in 34 patients with suspected graft infection, in 12 of them before the start of antimicrobial treatment. Diagnostic accuracy was assessed using a new five point visual grading score and by using a binary score. Maximum standardized uptake values (SUVmax) were calculated for quantitative measurements of metabolic activity, and cut off points were calculated using the receiver operator curve (ROC). The standard of reference was a microbiological culture, obtained after open biopsy or graft explantation. Results: Using the new scale, FDG-PET/CT correctly recognized 27 patients with graft infection, one patient was diagnosed as false positive, six patients were correctly classified as true negative, and no patients were rated false negative. Hence, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of FDG-PET/CT for the diagnosis of graft infections were 100%, 86%, 96%, 100%, and 97%, respectively. Using a previously established binary score, sensitivity, specificity, PPV, NPV, and accuracy were 96%, 86%, 96%, 86%, and 94% respectively. ROC analysis suggested an SUNmax cut off value of >= 3.8 to differentiate between infected and non-infected grafts (p<.001). Additionally, FDG-PET/CT provided a conclusive clinical diagnosis in six of seven patients without graft infection (i.e., other sites of infections). Conclusions: The diagnostic accuracy of FDG-PET/CT in the detection of aortic graft infection is high. A newly introduced five point visual grading score and early imaging prior to antimicrobial treatment may further improve the diagnostic accuracy. (C) 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available