4.2 Article

Comparison of Accuracy of Pedicle Screw Insertion Among 4 Guided Technologies in Spine Surgery

Journal

MEDICAL SCIENCE MONITOR
Volume 23, Issue -, Pages 5960-5968

Publisher

INT SCIENTIFIC LITERATURE, INC
DOI: 10.12659/MSM.905713

Keywords

Bone Screws; Fluoroscopy; Robotics; Surgery, Computer-Assisted; Templates, Genetic

Ask authors/readers for more resources

Background: As an available new tool for spinal surgery, robotic technology holds great potential and has been demonstrated to have better clinical outcomes compared with traditional techniques. However, it has not been compared with other assisted tools for the treatment of lumbar degenerative disease. This article focused on studying such variances. Material/Methods: A total of 176 pedicle screws were inserted in 39 patients using a spine robot (group 1), 134 screws were implanted in 28 patients using navigational template (group 2), 234 screws were implanted in 51 patients by O-arm-based navigation (group 3), and 346 screws were implanted in 72 patients by fluoroscopy-guided assistance (group 4). The screw position was evaluated using postoperative scans according to Rampersaud A to D classification, and other secondary data were also collected. Results: Perfect pedicle screw insertion (Grade A) was 90.34%, 91.79%, 84.19%, and 65.03% of groups 1-4, respectively. Clinically acceptable screw implantation (Grade A+B) was 94.32%, 95.52, 90.60%, and 78.03% in groups 1-4, respectively. Deviation sagittal (degrees) respectively was 3 +/- 9, 2 +/- 10, 4 +/- 7, and 10 +/- 8 degrees in groups 1-4, respectively. Deviation transversal (degrees) screw insertion was 3 +/- 8, 3 +/- 7, 4 +/- 9, and 8 +/- 13 degrees in groups 1-4, respectively. Statistical analysis showed group 1 had no significant difference in the accuracy of Perfect and Clinical acceptable as well as deviation sagittal or transversal, respectively, compared with groups 2 and 3 but not group 4. Conclusions: Robotic-assistance technology no clear advantage in terms of accuracy compared to the navigation template or O-arm systems for screw implantation, but it significantly reduced adverse events, fluoroscopy time per screw, postoperative stay, and blood loss.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available