4.1 Review

Serum Creatinine: Not So Simple!

Journal

NEPHRON
Volume 136, Issue 4, Pages 302-308

Publisher

KARGER
DOI: 10.1159/000469669

Keywords

Glomerular filtration rate; Serum creatinine; Jaffe

Ask authors/readers for more resources

Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDMS traceability), analytical interferences, analytical coefficient of variation (CV), biological CV and critical difference. Because the relationship between serum creatinine and glomerular filtration rate is hyperbolic, all these CVs will impact not only the precision of serum creatinine but still more the precision of different creatinine-based equations, especially in low or normal-low creatinine levels (or high or normal-high glomerular filtration rate range). (C) 2017 S. Karger AG, Basel