4.6 Article

Label-Free Colorimetric Nanosensor for the Selective On-Site Detection of Aqueous Al3+

Journal

ACS SUSTAINABLE CHEMISTRY & ENGINEERING
Volume 5, Issue 6, Pages 4552-4562

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acssuschemeng.6b02861

Keywords

Silver nanoparticles (AgNPs); Indole-2-carboxylic acid (I2CA); Density functional theory; colorimetric detection; Aluminum ions (Al3+); Aluminum nanoparticles (AlNPs)

Funding

  1. Ministry of Human Resource Development, Department of Higher Education, Government of India, under the scheme of Establishment of Centre of Excellence for Training and Research in Frontier Areas of Science and Technology (FAST) [5-5/201 4-TS. VII]

Ask authors/readers for more resources

Aluminum is a hazardous element, found abundantly in the environment. Although many methods have been reported for the efficient detection of aluminum, an easy and accessible sensor for fast detection of aqueous aluminum has not been devised to date. In this approach, we have synthesized indole-2-carboxylic acid capped silver nanoparticles (I2CA-AgNPs) using a one-pot method and used them as label-free nanosensors for the detection of Al3+ in the presence of interfering metal ions. I2CA-AgNPs were synthesized by two methods at different temperatures AgNPs synthesized by the heating method were further used as detection probes as they showed a strong and narrow surface plasmon resonance (SPR) peak in the visible region. The sensitivity of the detection probe has been optimized by variations in size and distribution of nanoparticles. Synthesized AgNPs were characterized by UV-vis spectroscopy, high-resolution transmission electron microscopy (HRTEM), Fourier transform infrared (FT-IR), zeta potential, and dynamic light scattering (DLS) analysis. Based on these results, I2CA-AgNPs could be used as colorimetric sensors to selectively detect the presence of Al3+. Further, results are confirmed by theoretical calculations of binding energy by density functional theory (DFT). Moreover, the nanosensor can also be applied to trace aluminum contamination in different types of water samples. The lower detection limit of the proposed method is 0.01 ppm (S/N = 3) which falls in the permissible limit set by the United States Environmental Protection Agency (USEPA), i.e. 50 ppm.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available