4.1 Article

A software tool to assess uncertainty in transient-storage model parameters using Monte Carlo simulations

Journal

FRESHWATER SCIENCE
Volume 36, Issue 1, Pages 195-217

Publisher

UNIV CHICAGO PRESS
DOI: 10.1086/690444

Keywords

solute transport; inverse modeling; tracer; transient storage; hyporheic zone; parameter estimation; OTIS; MCAT; OTIS-MCAT

Funding

  1. National Science Foundation (NSF) [EAR 1331906]
  2. NSF [EAR 1505309]
  3. US Department of Agriculture (USDA) [2013-67019-21365]
  4. Lilly Endowment, Inc. through Indiana University (IU) Pervasive Technology Institute
  5. Indiana METACyt Initiative
  6. USGS Toxic Substances Hydrology Program
  7. Directorate For Geosciences
  8. Division Of Earth Sciences [1505309] Funding Source: National Science Foundation

Ask authors/readers for more resources

Researchers and practitioners alike often need to understand and characterize how water and solutes move through a stream in terms of the relative importance of in-stream and near-stream storage and transport processes. In-channel and subsurface storage processes are highly variable in space and time and difficult to measure. Storage estimates are commonly obtained using transient-storage models (TSMs) of the experimentally obtained solute-tracer test data. The TSM equations represent key transport and storage processes with a suite of numerical parameters. Parameter values are estimated via inverse modeling, in which parameter values are iteratively changed until model simulations closely match observed solute-tracer data. Several investigators have shown that TSM parameter estimates can be highly uncertain. When this is the case, parameter values cannot be used reliably to interpret stream-reach functioning. However, authors of most TSM studies do not evaluate or report parameter certainty. Here, we present a software tool linked to the One-dimensional Transport with Inflow and Storage (OTIS) model that enables researchers to conduct uncertainty analyses via Monte-Carlo parameter sampling and to visualize uncertainty and sensitivity results. We demonstrate application of our tool to 2 case studies and compare our results to output obtained from more traditional implementation of the OTIS model. We conclude by suggesting best practices for transient-storage modeling and recommend that future applications of TSMs include assessments of parameter certainty to support comparisons and more reliable interpretations of transport processes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available